Product Details:
Payment & Shipping Terms:
|
Model Number: | GAG-6002 | Usage: | Plastic Testing Machine |
---|---|---|---|
Speed Range: | 0.1~200rpm | Torque Accuracy: | 0.1%F.S. |
Torque: | 0~230Nm | Temperature Range: | 530mm*350mm*250mm (L*W*H) |
Standard: | ASTM D2732, ISO 11501 | Power Supply: | 3phase, AC380V, 50Hz, 30A |
High Light: | plastic testing equipment,plastic testing instruments |
Computerized Moving Die Rheometer Rubber Testing Machine Laboratory Equipment Instrument
Description
Torque Rheometer is a measuring system for studying the flow, plasticizing, heat and shear stability of polymers. This system consists of a platform and some function units, such as the mixer and extruder. The platform connected with a function unit can measure flow and compounding behaviors, critical processing parameters of temperature, pressure, torque and viscosity of polymers in the laboratory-requiring only small sample volume. This instrument, which is designed to an excellent system with high measuring precision, handling flexibility and testing reproducibility, has been widely implicated in science research, quality control, and process experiment.
Specifications
Standard: | GB/T16584 IS06502 |
Temperature: | room temperature to 200 Centigrade |
Heating-up: | 15 Centigrade/min |
temperature fluctuation: | ≤ ±0.3 Centigrade |
temperature resolution : | 0.1 Centigrade |
torque range: | 0-5N.M,0-10N.M,0-20N.M |
torque resolution: | 0.001NM |
Power: | 50HZ, ~220V±10% |
Pressure: | About 0.4Mpa |
Air-pressure requirement: | 0.5Mpa--0.65MPa (user prepare the dia 8 trachea) |
Environment temperature : | 10 Centigrade--20 Centigrade |
Humidity range: | 55--75%RH |
Compressed air: | 0.35-0.40Mpa |
Swing frequency : | 100r/min(about 1.67HZ) |
Swing angle: | ±0.5 Centigrade ,±1 Centigrade ,±3 Centigrade |
Printing: |
Date,time,temperature,vulcanization curve,temperature curve,ML,MH,ts1,ts2,t10,t50,Vc1,Vc2. |
Features
1. The instrument uses a real closed cavity, and the United States Alpha (the original Monsanto) same. Repeatability and test data are comparable to alpha. In the international industry in the leading position.
2. The instrument based on large-scale database development platform, temperature control device using software direct control and acquisition and processing. This technology leads the international trend.
3. The instrument has statistics, analysis, storage, comparison and other functions. User-friendly design, easy to operate.
Standard
GB/T1232, GB/T 1233, ISO667, ISO 289 ,ASTM D 1646, JIS K 6300,etc.
Applicable Industries